主管:中华人民共和国应急管理部
主办:应急管理部天津消防研究所
ISSN 1009-0029  CN 12-1311/TU

消防科学与技术 ›› 2023, Vol. 42 ›› Issue (8): 1126-1130.

• • 上一篇    下一篇

变电站电气柜火灾探测及分散式气体灭火装置设计

谢丹1, 李越1, 洪伟艺2, 曹馨3   

  1. (1. 国网山东省电力公司经济技术研究院,山东 济南 250021;2. 国安达股份有限公司,福建 厦门361023;3. 福建省机电装备过程监测及系统优化高校重点实验室,福建 厦门361021)
  • 出版日期:2023-08-15 发布日期:2023-08-15
  • 作者简介:作者简介:谢 丹(1984- ),男,山东济宁人,国网山东省电力公司经济技术研究院高级工程师,硕士,主要从事变电站、电化学储能电站消防设计与技术研究,山东省济南市槐荫区纬十路111号,250021。
  • 基金资助:
    基金项目:国网山东省电力公司科技项目(520625200009)

Design of distributed gas fire extinguishing device for substation electric gas cabinet

Xie Dan1, Li Yue1, Hong Weiyi2, Cao Xin3   

  1. (1. Economic and Technological Research Institute of State Grid Shandong Electric Power Company, Shandong Jinan 250021, China; 2. Guoanda Co., Ltd., Fujian Xiamen 361023, China; 3. Key Laboratory of Process Monitoring and System Optimization of Electromechanical Equipment of Fujian Province, Fujian Xiamen 361021, China)
  • Online:2023-08-15 Published:2023-08-15

摘要: 针对变电站电气柜分布分散,火灾扑救困难等问题,设计了一种可用于变电站电气柜火灾探测及分散式气体灭火装置,包括火灾特征参量探测、火灾信息数据传输、气体灭火装置、火灾状态监控等模块。火灾探测模块对变电站电气柜内弧光、温度、烟雾和火焰特征参量进行实时探测。各部分之间探测收集到的信息采用一对多组网方式的LoRa无线通信技术进行交互,各探测参量及灭火状态均可在监控端进行实时显示。气体灭火装置具有手动与自动两种控制模式,在自动模式下可根据火灾实时信息对发生火灾电气柜进行灭火。通过模拟灭火试验对装置性能进行了试验验证,结果表明,该装置对分散形式的电气柜的火灾探测准确可靠,能较好实现灭火功能,信息交互方式高效合理,可为变电站火灾安全提供可靠的技术支撑。

关键词: 变电站, 气体灭火, LoRa通信, 消防装置

Abstract: Abstract: This article proposes a dispersed gas extinguishing fire protection system that can be used in substations, aiming to solve the problems of scattered distribution of electrical cabinets and difficult fire fighting. The fire protection system consists of modules such as fire characteristic parameter detection, fire information data transmission, gas extinguishing equipment, and fire status monitoring. The fire detection module can real-time detect arc light, temperature, smoke, and flame characteristic parameters in substations. The information collected by each module is transmitted through a one-to-many network using LoRa wireless communication technology, and all detection parameters and extinguishing status can be displayed in real-time at the monitoring end. The gas extinguishing equipment has two control modes, manual and automatic. In the automatic mode, the equipment can extinguish the fire in the electrical cabinet based on real-time fire information. The performance of the equipment has been experimentally verified through simulated fire extinguishing experiments. The results show that the fire detection accuracy of the fire protection system for dispersed electrical cabinets is reliable, and the extinguishing function can be well completed. The information exchange method is efficient and reasonable, which can provide reliable technical support for fire safety in substations.