喷淋水幕抑制化工聚集区火灾效果研究

门金龙1,李景辉2,熊碧波1,陈志滔1   

  1. (1.广东石油化工学院 机电工程学院,广东 茂名 525000;2.应急管理部信息研究院,北京 100029)
  • 出版日期:2023-02-15 发布日期:2023-02-17
  • 作者简介:作者简介:门金龙(1988- ),男,河南驻马店人,广东石油化工学院机电工程学院副教授,博士,主要从事安全科学技术、化工安全、氢能安全、应急管理方面的研究,广东省茂名市茂南区官渡二路139号,525000。
  • 基金资助:
    广东省自然科学基金面上项目(z20210045);广东省高等教育学会实验室管理专业委员会基金项目(GDJ2022017);茂名市科技计划项目(2020543);横向课题(H20210209)

Study on the effect of suppressing fires of spraying water curtain on chemical agglomerations

Men Jinlong1, Li Jinghui2, Xiong Bibo1, Chen Zhitao1   

  1. (1. College of Mechanical and Electrical Engineering, Guangdong University of Petrochemical Technology, Guangdong Maoming 525000, China; 2. Information Research Institute, Ministry of Emergency Management, Beijing 100029, China)
  • Online:2023-02-15 Published:2023-02-17

摘要: 为了揭示不同工况下喷淋水幕对化工聚集区火灾抑制效果影响规律,建立了FDS数值模型,通过改变单一变量分别模拟水幕开合状态、不同水幕排数、不同水幕喷头高度下火灾发展过程,分析不同工况条件下火源温度变化规律和烟气蔓延规律。结果表明:喷淋水幕开启后,位于储罐上方及水幕帘后的测点温度峰值同比下降19%及36%,可有效抑制高温烟气层蔓延;双排水幕帘相比单排水幕帘在抑制火源温度及烟气蔓延更具成效;初始喷头高度5.8 m时,相比其他高度在降低温度、加速烟气沉降方面更具优势。

Abstract: In order to reveal the influence law of emergency sprinkler water curtain on fire suppression effect in chemical gathering area under different working conditions, this paper establishes an FDS numerical model, simulates the fire development process under the opening and closing state of water curtain, the number of water curtain rows and the height of water curtain nozzle respectively by changing a single variable, and analyzes the change law of fire source temperature and the law of smoke spread under different working conditions. The results are as follows: after the sprinkler water curtain is opened, The peak temperature at the measuring point above the storage tank and behind the water curtain decreased by 19% and 36%, which can effectively inhibit the spread of high-temperature smoke layer; The double row water curtain is more effective than the single row water curtain in restraining fire source temperature and smoke spread; When the initial nozzle height is 5.8 m, compared with other heights, it has more advantages in reducing temperature and accelerating smoke sedimentation.

Key words: chemical agglomeration area, spray water curtain, smoke and thermal insulation, temperature peak