摘要: 研究气体灭火剂在航空货运低压环境与常压环境下对 18650 型三元锂离子电池的灭火特性。基于低压实验舱和气体灭火系统,使用全氟己酮分别在常压 101 kPa 和低压 30 kPa下对热失控的锂离子电池进行灭火,记录灭火现象、温度变化,并分析空气中各相关气体组分变化。结果表明,常压下热失控表现为向外爆燃和持续明火燃烧,延长了灭火时间;低压低氧浓度环境在一定程度上减缓锂离子电池的热失控燃烧放热反应,有助于控制峰值温度,提高灭火效率;灭火过程中,灭火剂会增加氧气的消耗,低压时氧气消耗大于常压;常压下电池内部反应和二次燃烧更充分,向外释放更多热量,生成了更多二氧化碳,而低压时会有更多的一氧化碳产生。

关键词: 常压, 低压, 锂电池, 灭火, 温度特性, 气体组分

Abstract: The fire extinguishing characteristics of the gas extinguishing agent on 18650 ternary lithium ion batteries fire in the low- pressure of air cargo and normal- pressure environment was researched. Based on the low- pressure experimental chamber and the gas fire extinguishing system, perfluorohexanone was used to extinguish the thermal runaway of lithium ion batteries at 101 kPa of normal pressure and 30 kPa of low pressure. Fire extinguishing phenomenon and temperature changes were recorded and changes in relevant gas components in the air were analyzed. The results showed that thermal runaway under normal pressure manifests as outward deflagration and continuous open flame combustion, thus prolonging the fire extinguishing time. The low-pressure and low-oxygen concentration environment slowed the thermal runaway combustion exothermic reaction of the lithium ion batteries and helped control the peak temperature, improved the efficiency of fire extinguishing. In the process of fire extinguishing, the extinguishing agent would increase the consumption of oxygen, and the oxygen consumption at low pressure is greater than normal pressure. The internal reaction and secondary combustion of the batteries are more sufficient under normal pressure, releasing more heat outward and generating more carbon dioxide, while more carbon monoxide is produced at low pressure.

Key words: normal- pressure, low- pressure, lithium ion battery, extinguishing, temperature characteristics, gas component