主管:中华人民共和国应急管理部
主办:应急管理部天津消防研究所
ISSN 1009-0029  CN 12-1311/TU

Fire Science and Technology ›› 2023, Vol. 42 ›› Issue (1): 75-78.

Previous Articles     Next Articles

Study on fire protection design of air-supported membrane roof

Xie Tianguang1,2 , Lu Shichang1,2 , Huang Yiliang1,2
  

  1. (1. Tianjin Fire Science and Technology Research Institute of MEM, Tianjin 300381, China; 2. Tianjin Shengda Safety Technology Co., Ltd., Tianjin 300381, China)
  • Online:2023-01-15 Published:2023-01-15

Abstract:

According to the air- supported membrane forming principle and fire risk,taking an air-supported membrane building as an example, in view of the technical difficulties in the practical application of PVC air-supported membrane structure, the structural response analysis under fire condition was carried out to calculate the membrane surface stress and maximum displacement under different scenarios. Based on the membrane combustion experiment, the most unfavorable fire scenario is designed. Calculate the maximum temperature near the membrane structure, put forward the fire protection design scheme and verify the feasibility of the scheme.

Key words: